5 min read
Fridge not cooling: a safe diagnosis path
The checks that narrow a fridge fault down before a technician arrives, and the things not to touch.
When a fridge stops holding temperature, the cause is usually one of five things: power, airflow, the door seal, the defrost system, or the sealed refrigeration circuit. The first four can often be narrowed down safely. The fifth needs gauges and a technician.
Start with power and settings
Confirm the cabinet has power at the plug, that the socket is not on a tripped circuit, and that the thermostat has not been knocked to a warm setting or into a holiday mode. Check the controller display for a fault code.
If the compressor is silent and the interior light works, the fault may be the thermostat, the start relay or the control board. If the compressor is hot and humming but not running, stop and switch it off: a failing compressor or start circuit should not be left powered.
Check airflow and load
A fridge packed tight against the evaporator cannot circulate cold air. Pull product away from the rear and top vents, and check that the condenser at the back or underneath is not blocked by dust, packaging or a cupboard door.
On a coastal site, condenser fins often carry a mat of salt-laden lint. A soft brush and a vacuum will remove surface debris safely. Do not bend the fins or use a high-pressure hose.
Look at the door
Close the door on a sheet of paper at several points around the frame. If the paper slides out easily, the gasket is not sealing there. Check that the door is not sagging on its hinges and that nothing on the shelves is holding it open.
A gasket that no longer seals lets humid air in. That air condenses, then freezes, and the cabinet starts icing around the door frame while the rest of the interior warms.
Defrost faults and sealed systems
Ice building heavily on the back wall or evaporator, with water appearing after a manual defrost, points to a defrost fault: timer, heater, termination sensor or drain. That is a technician job, but it is usually repairable.
If the cabinet runs continuously and never gets cold, with no ice pattern and a warm condenser, the refrigerant charge may be low or the compressor may not be pumping. Both need pressure testing and leak detection. Topping up gas without finding the leak is a temporary fix at best.